BRAND : HEARTBEAT MEDICAL
Product Details:
Minimum Order Quantity 5 Piece
Size Large
Type Automatic External Defibrillators
Usage/Application Emergency
Model Name/Number AED-7000
Operation Mode Automatic
Category Type Defibrillator
Features
Three-step defibrillation process
Two-button operation
Extensive voice and visual prompts for the operator
Continuous event recording for reporting each use to a printer or computer
Weekly self-test to ensure readiness
Biphasic energy output
Lock-out protection to prevent inadvertent defibrillation
Specifications Defibrillator
Output: Biphasic Truncated exponential
Energy Sequence: 150, 150, 200J
Charge Time: 8 sec. to150J
10 sec. to 200 J NEW battery
Analysis Time: 9 sec.
The maximum time from the initation of rhythm analysis to readiness for discharge with a new battery: Less than 30 seconds
The maximum time from the initation of rhythm analysis to readiness for discharge after 6 shocks: Less than 35 seconds
The maximum time from the initation of rhythm analysis to readiness for discharge: Less than 25 seconds
Audible Prompts: 20 audible prompts
Visual Prompts: LED prompts
Controls: Two buttons – On/Off, Shock
Output Energy Accuracy: ±15% into impendance from 25 to 75Ω
The Maximum Voltage: 1200±50V
Output disabled when the patient impedance is outside limits: 20Ω to 200 Ω
Battery
Part No: CR123A-4X2
Non-Rechargeable: 12V DC. 3.0 Ah
Capacity: 100 discharges at 200 Joules or 120 discharges at 150 Joules
Shelf Life (25 15 10 years (5 years storage + 5 years standby)
5 years standby (after installation)
Physical
Dimensions: 303 X 216 X 89 mm
Weight: 2 kg
Operating Temperature 0 to 40
Operating Humidity: Relative humidity between 30% and 95% (non-condensing)
Storge Teperature: -20 to 55 (without battery)
Storge Humidity: Up to 93% (non-condensing) (without battery)
Standard Configuration
1 AED 7000 Machine
1 Pair of Pads
1 pcs Batteries
1 pcs Handbag
Description Automatic External Defibrillator AED 7000, which is a defibrillation device safe, portable and easy to use, can be applied in family and public place to give first aid for the sudden death symptom. The defibrillator can analyze the patient’s ECG, make a judgment for the patient’s cardiac condition and indicate whether the defibrillation is needed and the defibrillation strength, which not only enhances the success rate of defibrillation, but also reduces the injury of defibrillation to heart to the utmost extent. There is low requirement for the operator to use the device. The defibrillator will guide the operator to carry out defibrillation












Reviews
There are no reviews yet.