Due to the high volume of orders, orders may be processed with a slight delay

Search

In Stock

Multi Parameter Patient Monitor

20,000.00

Brand MONARCH

Product Details:

Minimum Order Quantity 10 Piece
Display Size 12.1′
Type of display TFT

Model MM-5012
Parameters Measured SPO2, Temperature, RESP, NIBP, PR, ECG
Suitable For Neonatal, Pediatric, Adult
No of Leads in ECG 5
Display waveform of Respiration Yes
SPO2 Measurement Technique Nellcor
Type of SPO2 probe Reusable
NIBP Cuff Supplied Adult
Temperature probe type Reusable

Owing to the sprawling infrastructure facility, we have been able to offer Digital Multi Parameter Patient Monitor. This patient monitor is precisely designed by using best quality of material under the guidance of skilled professionals in accordance with the set norms of industry. Offered patient monitor is well inspected on numerous stages by our quality controllers for assuring its flawlessness. Patrons can easily avail this patient monitor from us at competitive rates.

Features:
Anti-high frequency surgical unit
Low maintenance
Reliable performance

Other Details:
Anti-ESU, anti- defibrillator
Large volume of tabular and graphic trends information storage and easy to recall
Arrhythmic Analysis, Multi Lead ECG Waveforms Display in Phase, Real time ST segment analysis, pacemaker detection Drug calculation and titration table
Optional: EtCO2, IBP, Printer, CMS and VGA

Technical specifications:

ECG:

Lead Mode: 5 Leads or 3 leads
Lead selection: I, II, III, avR, avL, avF, V,
Gain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto

Respiration:

Method: Impedance between R-F(RA-LL)
Bandwidth: 0.3 ~ 2.5 Hz
Resolution: 1 rpm
Accuracy : ±2 rpm
Apnea Alarm: 10 ~ 40 S

SpO2:

Measuring Range: 0 ~ 100 %
Alarm Range: 0 ~ 100 %
Resolution: 1 %
Accuracy: 70% ~ 100% ±2 %, 0% ~ 69% unspecified
Actualization interval: about 1 Sec.
Alarm Delay: 10 Sec.

Temperature:

Channel: 2
Measuring and Alarm Range: 0 ~ 50 °C
Resolution: 0.1°C
Accuracy : ±0.1°C

HR and Alarm:

Range: Adult: 15 ~ 300 bpm, Neo/Ped: 15 ~ 350 bpm
Accuracy : ± 1% or ± 1bpm,which great
Resolution: 1 bpm
Diagnostic: 0.05 ~ 100 Hz
Calibration Signal: 1 (mV p-p), Accuracy:±5%
ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV

NIBP:

Method: Oscillometric
Mode: Manual, Auto, STAT
Pulse Rate Range: 40 ~ 240 bpm
Alarm Type: SYS, DIA, MEAN
Resolution Pressure:1mmHg
Accuracy Pressure Maximum Mean error: ±5mmHg
Maximum Standard deviation: ±8mmHg
Overpressure Protection

Pulse Rate:

Measuring and Alarm Range: 20~300bpm
Resolution: 1bpm
Accuracy : ±2bpm

 

 

Reviews

There are no reviews yet.

Write a review

Your email address will not be published. Required fields are marked *

Bestsellers

Holter ECG System , Model No. - TLC 5000

Original price was: ₹75,000.00.Current price is: ₹72,500.00.
(0 Reviews)

aqua 12T Multipara Monitor

Original price was: ₹50,000.00.Current price is: ₹48,000.00.
(0 Reviews)

Bistos BT-350 CTG Machine – Fetal Monitor

Original price was: ₹90,000.00.Current price is: ₹62,000.00.
(0 Reviews)

3 Channel Ecg Machine

Original price was: ₹51,000.00.Current price is: ₹50,000.00.
(0 Reviews)

Back to Top
Product has been added to your cart
Compare (0)